| 1) Contract Review and Design Input | |
| ¡æ Contract review is performance to incorporate the customer'srequirements as a principle design Input including the | |
| applicable Code and Standards . | |
|
¡æ Customer interface is performed by the Sales Department for clarificaation on the engineering and quality requirements. |
|
| 2) Design Output | |
| ¡æ Valve design is performed by qualified design engineer using computer program. | |
|
¡æ The design output documents are : - Valve Assembly and Part Drawings |
|
|
¡æ The design output documents are : - Valve Specification |
|
|
¡æ The design output documents are : - Actuator Selection Data for Motor Operated Valves |
|
|
¡æ The design output documents are : - Procrement Specification |
|
| 3) Design Verification | |
|
¡æ Design verification is performed by design review & design analysis by ANSYS program . |
|
|
¡æ Design Analysis Capabilities by ANSYS Program include : - Structural Analy sis |
|
|
¡æ Design Analysis Capabilities by ANSYS Program include : - Dynamic Analysis (including seismic analysis) |
|
|
¡æ Design Analysis Capabilities by ANSYS Program include : - Buckling Analysis |
|
|
¡æ Design Analysis Capabilities by ANSYS Program include : - Heat Transfer |
|
|
¡æ Design Analysis Capabilities by ANSYS Program include : - Thermal Analysis |
|
|
¡æ Design Analysis Capabilities by ANSYS Program include : - Computational Fluid Dynamic (CFD) |
|
|
¡æ Weak Link Analysis for Motor Operated Valves |
|
| 4) Design Validation | |
| Design validation has been performed by functional qualification test per ANSI B16.41/ASEM QME-1 or other applicable reqirements | |
| at the Wyle Laboratory in the U.S.A. and at Samshin's Facilities . | |
| 5) Equipment Qualification Test Facilities | |
| A. Steam Generator(Test Boiler) | |
| ¨ç Design Pressure : 2,500psig | |
|
¨è Design Temperature : 750¢µ |
|
| ¨é Operating Pressure : 2,250psig | |
| ¨ê Operating Temperature : Saturated Temperature 345¡É | |
| ¨ë Maximum Capacity : 2.4 ton/hr | |
| ¨ì Available Test : Popping Test , Flow Interruption Test, Hot Cyclic Test | |
| B. Safety Valve Test Facility | |
|
¨ç Design Temperature : 650¢µ |
|
|
¨è Design Pressure : 2,200psig |
|
|
¨é Source Vessel : 8§© |
|
|
¨ê Test Vessel : 1§© |
|
| ¨ë Available Test : Popping & Blow-down Tests | |
| C. Hot Water TestFacility | |
| ¨ç Source Vessel Design Pressure : 3,200psig |
|
|
¨è Source Vessel Design Temperature : 650¢µ |
|
|
¨é Source Vessel Capacity : 5§© x 2 Vessels |
|
|
¨ê Test Vessel Design Pressure : 2,500psig |
|
|
¨ë Test Vessel Capacity : 8§© |
|
| ¨ì Available Tests : Hot/Cold Cycle Test, Flow Interruption/ Initiation Test, Flow Reverse Test, and Fully Open Valve | |
| Disc Flow Test for Check Valve. | |
| D. Flow Measuring Facilities(Cv) | |
| For small, medium and large valves, Sizes : 1/2" to 24" | |
| E. Pipe Reaction End Loading & Static Seismic Test Rigs for Small, medium and large valves, Sizes: 1/2" to 36" | |
![]() |
6) Typical Structure of Flexible Wedge Gate Valve, Pressure Seal |
| 7) Typical Structure of Parallel Slide Gate valve, Pressure Seal | |
| 8) Typical Structure of Globe Valve, Pressure Seal | |
| 9) Typical Structure of Swing check valve, Pressure Seal | |
|
|